Overview
VOLTAGE: 100~240 VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT: 8A/4A FOR 115/230VAC
INRUSH CURRENT: 20/40 AMPS @ 115/230VAC
- *TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃, STORAGE -20℃ ~ 80℃
*HOLD UP TIME: 16ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
*EFFICIENCY: 80-85% TYPICAL AT 115V FULL LOAD
*POWER GOOD SIGNAL: ON DELAY 100ms TO 500ms
*OVER POWER PROTECTOIN
*OVER VOLTAGE PROTECTOIN
*SHORT CIRCUIT PROTECTION
*OVER CURRENT PROTECTION
*SAFETY: TO MEET UL, CUL, TUV, CCC
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
Output Voltage |
Output Current Min. |
Output Current Max. |
Regulation Load |
Regulation Line |
Output Ripple & Noise Max.[P-P] |
+5V |
0.5 |
20 |
±5% |
±50mV |
50mV |
+12V |
1 |
38 |
±5% |
±50mV |
-12V |
0 |
0.8 |
±5% |
±50mV |
120mV |
+3.3V |
0.5 |
20 |
±5% |
±50mV |
50mV |
+5VSB |
0.1 |
3.5 |
±5% |
±50mV |
50mV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Update +12V Min load 2A to 1A
|